Triacs
IH
IGTM
PGM PG(AV)
ITSM
dv/dt (c)
Holding
Current Peak Gate
(DC) Gate Trigger
Open
Current
(1) (8) (12) (14)
Peak One Cycle Surge
Peak Gate Average
(9) (13)
Power Dis- Gate Power
sipation Dissipation
(14)
IGT IGTM
Critical Rate-of-Rise of
Commutation Voltage at
Rated VDRM and IT(RMS)
Commutating di/dt = 0.54
Rated IT(RMS)/ms
Gate Unenergized
(1) (4) (13)
mAmps
Amps
MAX
15
15
15
15
25
25
25
25
15
15
15
15
25
25
25
25
20
20
20
20
30
30
30
30
30
30
50
50
50
50
50
50
50
50
50
50
50
50
Amps
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.6
1.6
1.6
1.6
1.6
1.6
1.8
1.8
1.8
1.8
1.8
1.8
Watts
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
15
15
18
18
18
18
18
18
20
20
20
20
20
20
Watts
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
60Hz
10
10
10
10
10
10
10
10
20
20
20
20
20
20
20
20
55
55
55
55
55
55
55
55
55
55
80
80
80
80
80
80
100
100
100
100
100
100
50Hz
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
16.7
16.7
16.7
16.7
16.7
16.7
16.7
16.7
46
46
46
46
46
46
46
46
46
46
65
65
65
65
65
65
83
83
83
83
83
83
See General Notes and Electrical Specification Notes on page 2-4.
Volts/µSec
TYP
1.0
1.0
1.0
1.0
2.0
2.0
2.0
2.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
dv/dt
Critical Rate-of-
Rise of Off-State
Voltage at Rated
VDRM
Gate Open
(1)
Volts/µSec
TC=
100°C
TC=
125°C
tgt I2t di/dt
Gate
Controlled
Turn-On
Time
IGT =
200mA
0.1µs Rise
Time
(10)
RMS Surge Maximum
(Non-
Rate-of-
Repetitive) Change of
On-State Cur- On-State Cur-
rent for
rent
Period of
8.3ms for
IGT = 200mA
with 0.1µs
Fusing
Rise Time
µSec
MIN
TYP
Amp2Sec Amps/µSec
40 30 2.5
0.41
20
35 25 2.5
0.41
20
30 20 2.5
0.41
20
25 15 2.5
0.41
20
50 40
3
0.41
20
45 35
3
0.41
20
40 30
3
0.41
20
35 25
3
0.41
20
40 30 2.5
1.6
30
40 30 2.5
1.6
30
30 20 2.5
1.6
30
30 20 2.5
1.6
30
50 40
3
1.6
30
50 40
3
1.6
30
40 30
3
1.6
30
40 30
3
1.6
30
50 40 2.5
12.5
50
50 40 2.5
12.5
50
40 30 2.5
12.5
50
40 30 2.5
12.5
50
100 75
3
12.5
50
100 75
3
12.5
50
75 50
3
12.5
50
75 50
3
12.5
50
60 40
3
12.5
50
60 40
3
12.5
50
200 120
3
26.5
70
200 120
3
26.5
70
150 100
3
26.5
70
150 100
3
26.5
70
125 85
3
26.5
70
125 85
3
26.5
70
250 150
3
41
70
250 150
3
41
70
220 125
3
41
70
220 125
3
41
70
150 100
3
41
70
150 100
3
41
70
Teccor Electronics, Inc.
(972) 580-7777
2-3
Triacs

3 Page

Q6008L5 pdf
Electrical Specifications
Gate Characteristics
Teccor triacs may be turned on between gate and MT1 terminals
in the following ways:
• With in-phase signals (using standard AC line) Quadrants I and
III are used.
• By applying unipolar pulses (gate always positive or nega-
tive)—with negative gate pulses Quadrants II and III are used
and with positive gate pulses Quadrants I and IV are used.
However, due to higher gate requirements for Quadrant IV, it
is recommended that only negative pulses be applied. If pos-
itive pulses are required, see sensitive triac sections of cata-
log or contact factory.
In all cases, if maximum surge capability is required, pulses
should be a minimum of one magnitude above IGT rating with a
steep rising waveform (1 µsec rise time).
Electrical Isolation
Teccor’s isolated triac packages will withstand a minimum high
potential test of 2500VAC (RMS) from leads to mounting tab,
over the operating temperature range of the device. See isolation
table below for standard and optional isolation ratings.
ELECTRICAL ISOLATION
FROM LEADS TO MOUNTING TAB
VAC (RMS)
Isolated **
TO-220AB
2500
Standard
4000
Optional *
* For 4000V isolation, use V suffix in part number.
** UL Recognized File E71639
MT2
MT2 POSITIVE
+
MT2
(-) I GT
GATE
-I G T
MT1
REF
MT2
(+) I GT
GATE
MT1
REF
MT2
+ IGT
(-) I GT
GATE
(+) I GT
GATE
MT1
-
REF
MT2 NEGATIVE
MT1
REF
Definition of Quadrants
THERMAL RESISTANCE (STEADY STATE)
R θ JC [R θ JA] (TYP.) °C/W
Type
0.8 Amp
1.0 Amp
4.0 Amps
6.0 Amps
8.0 Amps
10.0 Amps
15.0 Amps
25.0 Amps
TO-92
60 [135]
50 [95]
TYPE 1
TO-202AB
3.5 [45]
3.8
3.3
3.5
TYPE 2
TO-202AB
6 [70]
THERMOTAB
TO-220AB
NON-ISOLATED
TO-220AB
3.6 [50]
3.3
2.8
2.6
2.1
2.1 [45]
1.8
1.5
1.3
1.1
Triacs
2-6 Teccor Electronics, Inc.
(972) 580-7777

6페이지





Constitution10 Pages
Télécharger[ Q6008L5.PDF ]

Liens de partage


Fiche technique recommandé

RéférenceDescriptionFabricant
Q6008L5TriacsTeccor Electronics
Teccor Electronics
Q6008LH4Alternistor TriacsTeccor Electronics
Teccor Electronics
Q6008LH4Alternistor TriacsTeccor Electronics
Teccor Electronics
Q6008LTInternally Triggered Triacs (4 A to 15 A)Teccor Electronics
Teccor Electronics
Q6008LTHInternally Triggered Triacs (4 A to 15 A)Teccor Electronics
Teccor Electronics


RéférenceDescriptionFabricant
AAT3221The AAT3221 and AAT3222 NanoPower™ Low Drop Out (LDO) linear regulators are ideal for portable applications where extended battery life is critical.Skyworks
Skyworks
GFB60N03N-Channel Enhancement-Mode MOSFET, Advanced Trench Process Technology, High Density Cell Design for Ultra Low On-ResistanceGeneral Semiconductor
General Semiconductor
H6060The H6060 is a monolithic low-power CMOS device combining a programmable timer and a series of voltage comparators on the same chip.EM Microelectronic - MARIN SA
EM Microelectronic - MARIN SA
IT8772EThe IT8772E is a highly integrated Super I/O using the Low Pin Count Interface. It provides the most commonly used legacy Super I/O functionality plus the latest Environment Control initiatives, including H/W Monitor and Fan Speed Controller.ITE
ITE

Un datasheet est un document fourni par le constructeur du composant, où figurent toutes les données techniques sur le produit: puissance dissipée, courant maximal, tension de seuil, tension de claquage, température de stockage, etc. Ils sont en général fournis gratuitement, et se présentent très régulièrement sous la forme d'un document pdf.


Index : 0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z





www.DataSheet.fr    |   2017   |  Contactez-nous    |   Recherche